  keysight technologies infniium z-series oscilloscopes data sheet achieve new extremes C 63 ghz of real-time bandwidth on 1 or 2 channels C 33 ghz of real-time bandwidth on 2 or 4 channels
introduction achieve new extremes with the emergence of technologies pushing hundreds of gb/s, an oscilloscope must now have high bandwidth, low noise and fast processing. that is the idea behind the keysight technologies, inc. infniium z-series oscilloscopes. they feature up to 63 ghz of real-time oscilloscope bandwidth and the industrys lowest noise and jitter measurement foors. featuring C 63 ghz of real-time oscilloscope bandwidth C the industrys only upgradable channel oscilloscope in a single frame (from 2 to 4 channels) C the industrys lowest noise and jitter measurement foor C the industrys highest enob at bandwidths up to 63 ghz C the industrys deepest memory (up to 2 gpts) the infniium z-series captures rise times as fast as 5 ps (20/80). bandwidth sample rate memory depth 1 channel 2 channel 4 channel 1 channel 2 channel 4 channel standard maximum dsaz634a 63 ghz 63 ghz 33 ghz 160 gsa/s 160 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz634a 50 mpts 2 gpts dsaz632a 63 ghz 33 ghz 160 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz632a 50 mpts 2 gpts dsaz594a 59 ghz 59 ghz 33 ghz 160 gsa/s 160 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz594a 50 mpts 2 gpts dsaz592a 59 ghz 33 ghz 160 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz592a 50 mpts 2 gpts dsaz504a 50 ghz 50 ghz 33 ghz 160 gsa/s 160 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz504a 50 mpts 2 gpts dsaz334a 33 ghz 33 ghz 33 ghz 80 gsa/s 80 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz334a 50 mpts 2 gpts dsaz254a 25 ghz 25 ghz 25 ghz 80 gsa/s 80 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz254a 50 mpts 2 gpts dsaz204a 20 ghz 20 ghz 20 ghz 80 gsa/s 80 gsa/s 80 gsa/s 100 mpts 2 gpts dsoz204a 50 mpts 2 gpts
03 | keysight | infniium z-series oscilloscopes - data sheet at the extremes of electrical and optical measurements ... you need to make rise time measurements without being limited by scope bandwidth the z-series is keysight technologies second generation of enabling 63 ghz of oscilloscope bandwidth. realedge technology is implemented using a unique combination of time interleaving, frequency interleaving and proprietary signal processing. you need to see your signal and not oscilloscope noise the z-series leverages technology from the award-winning infniium 90000x and 90000q series oscilloscopes, which provide leading signal integrity specifcations. the z-series takes advantage of leading-edge indium phosphide chip technology and custom thin flm packaging technology, which ultimately leads to the lowest-noise-, real-time oscilloscope in the world. with industry-leading bandwidths, z-series scopes let you see your fastest signals as they really are. you need fast analysis and hardware acceleration the z-series has a capacitive touch screen, new processor and 16 gb of ram to ensure faster processing than previous- generation infniium oscilloscopes. advanced ic design and technology help you solve your biggest problems infniiums custom multi-chip modules feature indium phosphide chips and keysight proprietary packaging technology, enabling high bandwidth and low noise. realedge technology blocks enable 63-ghz real-time bandwidth.
04 | keysight | infniium z-series oscilloscopes - data sheet with 63 ghz of bandwidth to capture rise times as fast as 5 ps and recover clocks on nrz data rates as fast as 120 gbit/s, the z-series is the worlds fastest real-time oscilloscope. its four channels at 33 ghz make it ideal for 32 gb/s and greater serdes designs. in addition to providing leading-edge bandwidth, the z-series helps you to fnd your real edge, by featuring the industrys lowest noise and jitter measurement foor, which means less scope noise in your measurements and a truer depiction of your signal. z-series features the following to enable extreme digital analysis 1. full offine analysis 2. flexible user interface that supports multiple displays and multi-touch 3. two unique jitter separation algorithms, including bounded uncorrelated jitter (buj) breakdown 4. clock recovery on nrz data rates as fast as 120 gb/s 5. memory depth that captures milliseconds of data at 160 gsa/s the oscilloscope digital measurement and analysis capture, display and measure multiple real-time eyes simultaneously with the z-series. with its fat frequency response and low noise, the z-series is able to accurately measure jitter components such as isi. with the 63 ghz bandwidth, the z-series is able to effectively characterize the time interval error trend of high speed signals as well as fast rising edges, down to 5 ps.
05 | keysight | infniium z-series oscilloscopes - data sheet you need to easily compute both magnitude and phase infniium z-series oscilloscopes include a fast fourier transform (fft) for frequency domain (spectrum) analysis. the integrated fft offers an alternative to a dedicated spectrum analyzer. use the fft to compute both magnitude and phase and take advantage of several useful features to assist in spectral analysis. the fft can control span and resolution bandwidth. automatic measurements and markers measure spectral peak frequencies and magnitudes as well as deltas between peaks. use the amplitude demodulation (envelope mode) to measure rise and fall times on the entire envelope. z-series features the following to enable extreme realedge analysis C multiple fft windows including hanning, rectangular, blackman- harris, fattop, and hamming C peak search and navigation for fast analysis C amplitude modulation (envelope mode) create radar envelopes C fft mask trigger C gated fft measurements the spectrum analyzer radar and satellite communications analysis the z-series fft quickly identifes peaks and has key controls such as span, start and stop, which make the oscilloscope behave more like a spectrum analyzer. ampltitude demodulation makes it possible to analyze diffcult waveforms such as envelopes. use the fft mask to test frequency margins and capture rare events.
06 | keysight | infniium z-series oscilloscopes - data sheet the optical modulation analyzer z-series oscilloscopes are also available in combination with the n4391a optical modulation analyzer as a fully specifed turn-key instrument. this compact solution offers the highest bandwidth available on the market and is the most advanced test solution for advanced research on 400g and terabit transmission. even for the lower 20 ghz bandwidth range, this compact and easy-to-use solution is a reference system for 100g transmission required by r&d labs working at 100g and beyond. by providing four channels of up to 63 ghz bandwidth, the z-series saves you the expense of a second instrument to analyze dual polarization. if you prefer to operate with your own optical receivers but want to beneft from the enormous analysis capability, you can get the n4391as analysis software as a standalone package. features and benefts C up to 63 ghz true analog bandwidth on four channels by time synchronizing two 2-channel, 63 ghz scopes C up to 33 ghz true analog bandwidth on four channels in one scope C up to 120 gbaud symbol rate analysis C four times better evm noise foor than typical qpsk transmitter C compact four channels in turn-key solution C up to four 160 gsa/s real-time sampling for optimal phase tracking C well-defned interface to include your own matlab algorithms C customer-confgurable apsk and ofdm decoders the n4391a offers a powerful toolset to debug the most challenging errors, with tools proven by thousands of rf engineers
07 | keysight | infniium z-series oscilloscopes - data sheet you need to be able to maximize your margins by removing the effects of cables and fxtures as bandwidths continue to increase and cable loss becomes more and more of a problem, the z-series has the technology to solve this issue. the z-series oscilloscopes offer award-winning precisionprobe advanced technology. you no longer need to ignore cable loss because you are short on time or budget. using precisionprobe advanced technology, you can characterize cables as fast as 63 ghz and remove the loss they create. precisionprobe advanced technology gives you one of the worlds fastest edges at less than 5 ps and uses this edge to perform a tdt on your cable. based on the loss of your cable, precisionprobe advanced then compensates your measurement system, gaining back valuable margin typically lost in cables. you need to test multiple lanes automatically and still maximize margins the z-series features many compliance applications, which provide full automation of any switch connected to your system. the software is fully compatible with precisionprobe advanced compensation, which allows you to characterize every input using only your z-series oscilloscope and then seamlessly automate every measurement in your compliance application. save valuable time and resources in such technologies as displayport and pci express ? gen3. by analyzing cables you can increase your margins by removing insertion loss caused by cables. the network analyzer time-domain transmission (tdt)
08 | keysight | infniium z-series oscilloscopes - data sheet the worlds fastest probing system for your highest performance needs the infniimax iii and iii+ probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fdelity and accuracy. eight different infniimax probe amplifers ranging from 8 to 30 ghz are available for matching your probing solution to your performance and budget requirements. the infniimax iii and iii+ probe system is unmatched by any product in the market. it uses a proprietary 200 ghz transistor switching speed indium phosphide ic process with backside ground vias and novel thick-flm technology to accommodate your highest-performance needs. description probe or accessory bandwidth 30-ghz infniimax iii probe amplifer n2803a 30 ghz 25-ghz infniimax iii probe amplifer n2802a 25 ghz 20-ghz infniimax iii probe amplifer n2801a 20 ghz 16-ghz infniimax iii probe amplifer n2800a 16 ghz 20-ghz infniimax iii+ probe amplifer n7003a 20 ghz 16-ghz infniimax iii+ probe amplifer n7002a 16 ghz 13-ghz infniimax iii+ probe amplifer n7001a 13 ghz 8-ghz infniimax iii+ probe amplifer n7001a 8 ghz zif probe head n5439a 28 ghz browser (handheld) probe head n5445a 30 ghz solder-in probe head N5441A 16 ghz pc board zif tip n2838a 25 ghz 3.5/2.92/sma probe head n5444a 28 ghz performance verifcation fxture n5443a 30 ghz solder-in probe head n2836a 26 ghz 450-ohm zif tip kit (set of fve) n5440a 28 ghz 200-ohm zif tip kit (set of fve) n5447a 28 ghz browser tip replacement n5476a 30 ghz precision bnc adaptor n5442a 13 ghz sampling scope adaptor n5477a 30 ghz 2.92-mm fexible cable n5448b 30 ghz high-impedance probe adaptor n5449a 500 mhz 35-ghz fexible cable n2812b 35 ghz industrys only upgradable probing system.
09 | keysight | infniium z-series oscilloscopes - data sheet achieve your real edge 10 gbps eye captured with 20 ghz of bandwidth. 10 gbps eye captured with 30 ghz of bandwidth. 10 gbps signal captured with 63 ghz of bandwidth. notice the faster rise time and wider eye measurements. having the right amount of oscilloscope bandwidth ensures accurate measurements. if you have too much bandwidth, oscilloscope noise becomes a contributor in your measurement. with too little bandwidth, rise times are improperly depicted. use the chart below to fnd the correct oscilloscope bandwidth for the devices you are measuring. recommended scope bandwidth technology data rate fastest rise time scope bw ethernet 10base-t 10 mbps 30 ns 600 mhz ethernet 100base-t 100 mbps 3 ns 600 mhz ethernet 1000base-t 250 mbps x 4 1.2 ns 1 ghz usb 2.0 480 mbps 300 ps 2.5 ghz usb 3.0 5 gbps 50 ps 12 ghz usb 3.1 10.3125 gbps 25 ps 25 ghz ddr1 400 mt/s 500 ps 2 ghz ddr2 1066 mt/s 250 ps 4 ghz ddr3 2133 mt/s 100 ps 8 ghz ddd4 3200 mt/s 75 ps 12 ghz gddr5 8 gbps 30 ps 16 ghz sata 3g 3 gbps 67 ps 12 ghz sata 6g 6 gbps 33 ps 16 ghz sas-2 6 gbps 42 ps 16 ghz sas-3 12 gbps 21 ps 30 ghz 16g fibrechannel 14.025 gbps 24 ps 30 ghz hdmi 1.4 3.4 gbps 50 ps 8 ghz displayport 1.2 17.28 gbps 50 ps 13 ghz 10g ethernet 10 gbps 60 ps 12 ghz 10gbase-kr 10.3125 gbps 24 ps 25 ghz xaui 3.75 gbps 60 ps 12 ghz mipi ? m-phy ? 5.83 gbps 17. 2 p s 24 ghz mipi d-phy sm 2.5 gbps 100 ps 6 ghz pci express 2 5 gbps 30 ps 12.5 ghz pci express 3 8 gbps 25 ps 20 ghz 28/32g fibrechannel 28 gbps 18 ps 45 ghz thunderbolt 10g 10.3125 gbps 22 ps 25 ghz sfp + 10 gbps 34 ps 16 ghz mhl 2.25 gbps 75 ps 8 ghz infniband ii 2.5 gbps, 5 gbps 75 ps 8 ghz 10 gbps eye captured with 10 ghz of bandwidth.
10 | keysight | infniium z-series oscilloscopes - data sheet 63 ghz of true analog bandwidth and 160 gsa/s on two channels. see your signal more clearly with a large 15.4-inch capacitive touch-screen display. 16 gb ram standard, quad core i5 processor and hardware acceleration enable fast processing. remote access through ethernet 10/100/1000base-t lan interface with web-enabled connectivity uses ultra- responsive ultravnc. usb and lan provide remote measurements. infniium application remote program interface (now a standard feature) allows application/compliance software automation. calibration edge with a rise time of less than 15 ps enables tdt calibration with precisionprobe. use the infniium calibration source as part of precisionprobe advanced to extend calibration to an unmatched 63 ghz. threaded rf connectors ensure the most reliable signal integrity for high-performance instruments. the autoprobe ii interface combines the tried-and-true 3.5-mm threaded rf connector of keysight sampling oscilloscopes with a convenient automatic torque mechanism that ensures a consistent 8 in. lbs. connection without the hassles of a torque wrench. achieve new extremes introducing infniium z-series oscilloscopes
11 | keysight | infniium z-series oscilloscopes - data sheet the z-series improves upon keysights use of custom integrated circuits and multichip module packaging with an exclusive technology called realedge. realedge comprises a combination of new architectures, next- generation microcircuits and thin-flm components, and advanced application of keysights indium phosphide semiconductor process. this technology enables high-frequency capability while maintaining the industrys lowest noise and jitter measurement foor (75 fs). 100-mhz reference clock ties up to 10 z-series together with 150 fs precision. a 10-mhz clock allows tying multiple instruments together with the z-series. live indicator shows when the scope is running a long operation. measure section, including a toggling marker button and a dedicated marker knob, provides quick access to your marker control. individual vertical knobs per channel. the horizontal and vertical knobs can be changed to control functions and waveform memories. simply right click the channel control in the gui to change these controls.
12 | keysight | infniium z-series oscilloscopes - data sheet infniium user interface easy-to-use ffts. amplitude demodulation. protocol decode. achieve new extremes (continued)
13 | keysight | infniium z-series oscilloscopes - data sheet the infniium user interface features: C full offine viewer C up to 4 grids C up to 16 functions C up to 16 horizontal gates C up to 9 jitter analysis charts C up to 9 noise analysis charts C up to 4 infniisim charts C up to 16 ffts at once C up to 16 grids in each window C peak annotation C composite fles for easy fle sharing C on-screen marker measurements C up to 20 measurements displayed at once C multiple display support C drag and drop measurements C my infniium menu customization C up to 16 user-defned functions C full spectral window C spectral analysis controls C quick save C multi-touch for touch capacitive screen C function overviews/window C up to 16 measurement trends C up to 16 histograms C nearly unlimited real-time eyes C tail ft versus spectral analysis chart C hardware acceleration C plus much more protocol decode. up to 16 horizontal gates. jitter algorithm verifying window.
14 | keysight | infniium z-series oscilloscopes - data sheet achieve new extremes (continued) the z-series features the industrys lowest noise and jitter measurement foors, allowing you to truly see your signal and get your device to market faster. by characterizing and compensating for loss in cables, you can gain signifcant margin. precisionprobe makes using switches easy in your test setup. debugging next-generation buses such as pci express and thunderbolt require advanced analysis tools. keysights infniisim software helps you model the most diffcult situations. infniium z-series oscilloscopes are the worlds only 4-channel, 33-ghz real-time oscilloscopes. z-series scopes are the only oscilloscopes that feature 30-ghz probes, making debugging your system easier and ensuring you arent missing valuable harmonic content. low noise and jitter precisionprobe waveform transformation
15 | keysight | infniium z-series oscilloscopes - data sheet z-series oscilloscopes features application-specifc software that allows you to gain the insight into your design that you need. whether you are solving tough jitter or noise problems, removing loss due to cables or probes, or simply looking at protocol, the z-series has the tools to help you ensure you realize your best design. keysights compliance software packages are certifed by experts and provide assurance that when you pass in-house, you will pass at your customer site as well. infniium protocol tools simplify debugging your design. infniium scopes offer full protocol analysis for pci express gen 1, 2, and 3. the 128b/130b decoding features a lister that makes alignment between the lister and analog channels simple. infniiums new noise analysis tools allow you to analyze your data bus completely. advanced jitter and noise separation protocol analysis compliance software
16 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: precisionprobe basic and advanced (n2809a and n2807b) pci express measurement comparisons root complex device eye height (mv) eye height precisionprobe gain (%) 2.5 gt/s 12 ghz 517.19 553.94 7.1 5 gt/s_12 ghz_3.5 db 312.22 348.19 11.5 5 gt/s_12 ghz_6 db 341.1 376 10.2 5 gt/s_16 ghz_3.5 db 306.6 348.33 13.6 5 gt/s_16 ghz_6 db 344.4 374.41 8.7 8 gt/s_12 ghz_p7 96.83 103.09 6.5 8 gt/s_12 ghz_p8 100.16 108.33 8.2 8 gt/s_16 ghz_p7 96.92 106.01 9.4 8 gt/s_16 ghz_p8 100.24 108.24 8.0 by characterizing and compensating for cable loss on the cable connected to the pci express test fxture, the designer was able to gain between 6.5 and 13.6% margin that would have been lost otherwise. every z-series oscilloscope has keysights custom indium phosphide (inp) fast edge. turn your z-series oscilloscope into a time-domain transmissometry (tdt). quickly characterize and compensate any input into your scope. precisionprobe technology turns your oscilloscope into the ultimate characterization tool. not only can you do the normal waveform transformations such as de-embedding through infniisim, precisionprobe allows quick characterization of your entire probe system (including cables and switches) without the need for extra equipment. precisionprobe takes advantage of the fast cal output signal built into the z-series to characterize and compensate insertion loss on the measurement system. precisionprobe technology: C properly creates custom probe transfer function = vout/vin C properly characterizes probed system transfer function such that vout/vin = vout/vsrc C removes unwanted s21 cable loss now every probe and cable in the system can have the exact same response probe to probe or cable to cable without the inaccuracies that using one model can produce. you can properly characterize custom probes and remove unwanted responses. in addition to characterizing the cables, precisionprobe allows for immediate use on the same instrument. precisionprobe saves you time and money while increasing your measurement accuracy. when you combine infniimax probes with switches between the amplifer and the probe head, precisionprobe allows for full correction and automation of each probes path. full automation is then available to allow for quick swapping of the inputs via infniiums compliance framework. for increased accuracy, purchase precisionprobe advanced for faster edge speeds and true differential measurements.
17 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: ezjit, ezjit plus and sda (standard on dsa models) use ezjit software to extract spread spectrum clocks. determine which algorithm fts your data best. jitter separation makes debugging your device easy. with faster edge speeds and shrinking margins in todays high-speed digital designs, insight into the causes of jitter has become critical for success. using ezjit and ezjit plus jitter analysis software the z-series oscilloscopes help you identify and quantify jitter margins that affect the reliability of your design. time correlation of jitter to the real-time signal makes it easy to trace jitter components to their sources. additional compliance views and a measurement setup wizard simplify and automate rj/dj separation for testing against industry standards. ezjit plus automatically detects embedded clock frequencies and repetitive data patterns on the oscilloscope inputs and calculates the level of data-dependent jitter (ddj) that is contributed to the total jitter (tj) pdf by each transition in the pattern, a feature not available on any other real-time oscilloscope today. measurement trends and jitter spectrum ezjits simple tools help you quickly analyze the causes of jitter. measurement trends allow you to see deeper views of factors affecting measurements. jitter spectrum is a fast method to fnd the causes of jitter. two ways to separate jitter ezjit plus comes with two ways to separate jitter: the spectral method and the emerging tail ft method. both methods allow for simple separation of rj and dj, but the tail ft method provides proper jitter separation in the unique case of bounded uncorrelated jitter. unique rj/dj threshold view ezjit plus also provides a unique threshold view of the jitter spectrum with the threshold drawn on the chart. the spectral view provides insight into the decision point of the separation and works with both narrow and wide spectral separation. real-time eye and clock recovery serial data analysis (sda) software provides fexible clock recovery including 1st and 2nd-order pll and constant algorithms. with a stable clock, you can look at real-time eyes of transition and non-transition bits. z-series scopes with sda software also provide a new unique view of bits preceding an eye. flexible charts ezjit plus displays up to 10 graphs with unique information. use them all to maximize your jitter analysis. gain insight into the causes of signal jitter to ensure high reliability of your design
18 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: ezjit complete (standard on dsa models) discover signal anomalies to the noise of the waveform more than your standard jitter package to effciently determine root cause for any type of signal degradation in the amplitude domain, you must frst determine whether the problem is caused by random or deterministic sources. to help you accomplish this task, ezjit complete takes analysis techniques used in the time domain (jitter analysis) and extends them into the amplitude domain. more than just an eye contour ezjit complete is an in-depth view into impairments related to signal levels C either logic ones or logic zeroes C deviating from their ideal positions. some tools simply provide a view of an eye contour, but provide no real measurement data other than nice graphics. ezjit complete uses separation techniques to allow each bit to be examined to determine correlated effects and to make multiple measurements on individual bits to determine uncorrelated effects. use ffts to analyze the frequency domain and extract random components. dual-dirac modeling techniques are also carried from the jitter domain and used in the interference domain. key measurements with ezjit complete, z-series scopes offer the following unique measurements: C total interference (ti) C deterministic interference (di) C random noise (rn) C periodic interference (pi) C inter-symbol interference (isi) C rin (dbm or db/hz) C q-factor noise analysis with ezjit complete software for insight into the sources of noise in the signal.
19 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: infniisim (n5465a) the most advanced waveform transformation software helps you render waveforms anywhere in a digital serial data link infniisim waveform transformation toolset provides the most fexible and accurate means to render waveforms anywhere in a digital serial data link. the highly confgurable system modeling enables you to remove the deleterious effects of unwanted channel elements, simulate waveforms with channel models inserted, view waveforms in physically improbable locations, compensate for loading of probes and other circuit elements, and do so simply and quickly on your tool of choice, the z-series at up to 63 ghz of bandwidth. circuit models to defne your setup the infniisim waveform transformation toolset provides a graphical user interface for you to defne your system as you understand it and even make it arbitrarily complex. you do this by selecting topologies and defning circuit blocks. model refections with the infniisim waveform transformation toolset, you can transform signals with confdence, whether you are inserting or removing channel elements or relocating the measurement plane. infniisims advanced toolset lets you model up to 27 different elements at once and model the interaction between elements. only toolsets with the ability to model more than one element will properly refect a model including the oscilloscopes input. the z-series scopes provide their own s11 parameter to allow modeling of their own input. model your system with as much detail as you need infniisim features the model setup that best matches your design. whether it is a simple single-element model or an advanced general-purpose model with up to 27 elements in the link, you can perfectly model your design and simulate the exact probing point you want. infniisim renders the waveform through hardware acceleration. infniisim allows embedding and de-embedding of up to 27 different elements or s-parameter models at once to meet your most demanding requirements.
20 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: serial data equalization (n5461a) signifcantly reduce receiver errors by opening even tightly shut eyes through equalization emulation serial data equalization for the z-series provides fast and accurate equalization using decision feedback equalization (dfe), feed-forward equalization (ffe), and continuous-time linear equalization (ctle) modeling in real-time. serial data equalization software allows you to input your own self-designated tap values to verify your design. if you prefer, the software will fnd the optimal tap values for you. ctle allows dc gain and two-pole modeling. analysis tools: infniiscan (n5 414b) trigger on events that hardware triggers cant handle infniiscan software allows you to use an oscilloscope to identify signal integrity issues that hardware triggering is unable to fnd in your electronic designs. this innovative software scans through thousands of acquired waveforms per second to help you isolate signal anomalies, saving you time and improving designs. innovative triggers the zone qualify fnder allows you to draw a must intersect or must not intersect zone on the oscilloscope screen to visually determine the event identify condition. if you can see the event of interest on the screen, you can create a trigger that will isolate it, saving signifcant time over some complicated hardware triggers. other triggers include non-monotonic edge, measurement limit search, runt and pulse width. draw zones on your screen for a unique triggering experience.
21 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: n8900a infniium offine oscilloscope analysis software view and analyze away from your oscilloscope and target system ever wish you could do additional signal viewing and analysis away from your scope and target system? now you can. capture waveforms on your scope, save to a fle, and recall into keysights infniium offine application. view and analyze anywhere your pc goes take advant age of large high-resolution and multiple displays found in your offce. use familiar scope controls to quickly navigate and zoom in to any event of interest. use auto measurements and functions for additional insight. share scope measurements more easily across your team you can share entire data records instead of being limited exclusively to static screen shots. create more useful documentation use features such as right-click cut-and-paste to move screen images between applications, without ever having to save the image to a fle. add up to 100 bookmark annotations and up to 20 simultaneous measurements. need advanced analysis capability? infniium offine includes a variety of upgrade options including serial decode upgrades for a variety of serial buses, jitter analysis, and serial data analysis. infniium offine software works with all of infniiums applications. use infniium offine to fnd signal anomalies, such as power supply coupling. peak search capability makes infniium offine a frequency domain tool.
22 | keysight | infniium z-series oscilloscopes - data sheet analysis tools: user-defned function (n5430a) combine infniium and matlab for even more analysis enhance the z-series with a seamless gateway to powerful matlab analysis functionality. user-defned function software adds new analysis capabilities to the z-series, beyond traditional math/analysis features. now you have the freedom to develop your own math functions or flters using matlab and its signal processing toolbox. with a seamless integration to matlab, infniium oscilloscopes allow you to display your math and analysis functions live on the oscilloscope screen, just like any other scopes standard functions. analysis tools: complete list of analysis software description license type fixed floating factory-installed on new oscilloscope or user-installed on existing oscilloscope user-installed transportable license server-based license ezjit complete jitter analysis n8 823a-1fp n8 823a-1tp n5435a-067 ezjit plus jitter analysis n540 0a-1fp n540 0a-1tp n5435a-001 ezjit jitter analysis e2681a-1fp e2681a-1tp n5435a-002 frequency domain analysis n8832a-001 high-speed sda and clock recovery e2688a-1fp e2688a-1tp n5435a-003 infniiscan software triggering n5414b-1fp n5414b-1tp n5435a-004 infniisim advanced signal de-embedding n5465a-1fp n5465a-1tp n5435a-027 infniisim basic signal de-embedding n5465a-3fp n5465a-3tp n5435a-026 matlab - basic digital analysis n8831a-001 matlab - standard digital analysis n8831a-002 multiscope software - combines two scopes 1 n8834a-atp n5435a-085 multiscope software - combines up to fve scopes 1 n8834a-btp n5435a-086 multiscope software - combines up to ten scopes 1 n8834a-ctp n5435a-090 pulse amplitude modulation (pam-4) analysis n8 827a-1fp n8 827a-1tp n5435a-077 precisionprobe calibration 2 n2809a-1fp n2809a-1tp n5435a-044 serial data equalization n5461a-1fp n5461a-1tp n5435a-025 user-defned function n54 30a-1fp n54 30a-1tp n5435a-005 1. supports any combination of infniium oscilloscope models with software 5.50 and above. 2. compliance software is not supported on dsaz632a, dsoz632a, dsaz592a and dsoz592a scope models.
23 | keysight | infniium z-series oscilloscopes - data sheet compliance and automated testing compliance applications make testing to todays technologies standards easy. the remote programming interface makes it easy to control automation applications via your pc. precisionprobe is fully integrated in z-series automation applications. todays demanding environment means you have much less time to understand the intricacies of the technologies you are testing. you also have less time to develop and test automation software that is designed to increase measurement throughput and decrease time to market. compliance applications save you time and money with measurement automation built into the compliance application. no longer do valuable resources need to be exclusively tied to writing automation software. instead they can be deployed to designing the next big project. infniiums compliance applications are fully functional with design tools such as ads. imagine running your waveforms at design through the entire suite of compliance tests, giving more insight earlier than was previously possible. as the design moves to silicon and then to validation, the same suite of tests can be run live on your device. compliance applications that run on z-series oscilloscopes are certifed to test to the exact specifcations of each technology standard. if a test passes on the z-series scope in your lab, you can be assured that it will pass in test labs and at plug fests worldwide. keysight experts on technology boards and industry standards committees help defne compliance requirements. as a result, you can be sure that z-series oscilloscope tools deliver to critical specifcations. setup wizards combined with intelligent test fltering give you confdence youre running the right tests. comprehensive html reports with visual documentation and pass/fail results guarantee that critical information is retained on each test. quick and easy automated switching only keysights z-series oscilloscopes feature compliance applications with both the user-defned applications add-in capability and integrated precisionprobe compensation. switch paths can vary in their characteristics and have unwanted loss. by enabling precisionprobe in its compliance applications, z-series scopes allows you to characterize and compensate for every path in the switch, making every paths frequency response identical in both magnitude and phase. these tools makes switch automation quick and painless. the z-series and its compliance applications make automation more automated than ever. your technicians no longer need to spend valuable time physically changing connections.
24 | keysight | infniium z-series oscilloscopes - data sheet compliance and automation testing: user-defned application (n5467b) custom automation for your z-series oscilloscope the user-defned application is the only fully customizable automated environment made for an oscilloscope by an oscilloscope designer. it provides full automation, including the ability to control other keysight instruments, external applications such as matlab and your dut software. simplify your automation the user-defned application (uda) makes automation simple. the application takes the infniium compliance application framework and gives you full access to its interface. uda allows for automation testing in as little as one minute. use uda to control other keysight instruments such as signal generators and network analyzers to create a full suite of measurements. full measurement report no automation would be complete without a simple-to-view and easy-to-understand report. uda provides a full report of the pass/fail criteria you have provided. add-in capability ever wanted to add testing to your compliance applications? all infniium compliance applications support the industrys most fexible testing mechanism with uda add-in capability. create the custom testing you need and then plug it into your compliance application to expand the application to your testing needs. uda add-in capability is available only on infniium oscilloscopes. precisionprobe and switch compatibility uda makes automation of switches in your system simple and accurate. use precisionprobe to characterize the path of the switch and then let udas unique gui switch between every input in your switch system. every input can look identical in its frequency response thanks to this advanced technology. customize your own tests and requirements with user-defned application in the familiar keysight framework. add a switch when testing your multi-lane signals to automate tedious test requirements.
25 | keysight | infniium z-series oscilloscopes - data sheet compliance and automation testing: switch matrix support comprehensive testing, easily achieved eliminate reconnections (reducing errors) compliance applications on the z-series support a switch matrix, making testing simple by automating tests for each lane of a multi-lane bus. typical testing requires reconnecting the oscilloscope each time you switch a lane, which causes wasted time and inaccuracies. the z-series solves this problem by supporting switch matrix through its compliance test. simply connect the switch to the oscilloscope and all the lanes, and then click run to complete full testing of your entire device. maintain accuracy the framework fully supports keysights precisionprobe software (n2809a) and infniisim software (n5465a). this gives you the ability to characterize every switch path to the device under test (both magnitude and skew) and ensure that all of them maintain the same level of accuracy. customize your testing use the remote programming interface (standard feature on the z-series) and n5467a user-defned application for device control, instrument control and test customization. skews between switch paths are easily maintained with keysights unique software. typical switch confguration for hdmi testing (now supported in the z-series). software description model number fixed 1 floating 2 node locked transportable server based displayport switch matrix u7232c-7fp u7232c-7tp n5435a-701 hdmi switch matrix n5399c-7fp n5399c-7tp n5435a-702 mipi d-phy switch matrix u7238c-7fp u7238c-7tp n5435a-703 mipi m-phy switch matrix u7249c-7fp u7249c-7tp n5435a-704 pcie ? switch matrix n5393d-7fp n5393d-7tp n5435a-705 ethernet kr switch matrix n8814b-7fp n8814b-7tp n5435a-706 qsfp+ switch matrix n6468a-7fp n6468a-7tp n5435a-707 uda switch matrix n5467b-7fp n5467b-7tp n5435a-708 100gbase-cr10 switch matrix n8828a-7fp n8828a-7tp n5435a-709 100gbase-kr4 switch matrix n8829a-7fp n5435a-710 n8829a-7tp 100gbase-cr4 switch matrix n8830a-7fp n8830a-7tp n5430a-711 10gbase-t switch matrix n5392a-7fp n5392a-7tp n5430a-712 1. factory-installed on new scope purchase or user-installed on existing scope. 2. must be user-installed. dut scope sma probe head sma probe head sma probe head sma probe head switch matrix +3.3v l3 ch4 ch3 ch2 ch1 l2 l1 clock
26 | keysight | infniium z-series oscilloscopes - data sheet compliance and automation testing: other options on z-series oscilloscopes in the previous pages we have highlighted a few of the key technologies that beneft from the industrys only four-channel oscilloscope with more than 20 ghz bandwidth. the z-series offers over 20 compliance applications and the list continues to grow. all applications are fully compatible with infniisim, precisionprobe and udas unique add-in capability. compliance test and validation software 1 description license type fixed floating factory-installed on new oscilloscope or user-installed on existing oscilloscope user-installed transportable license server-based license broadr-reach n6 467a-1fp n6 467a-1tp n5435a-062 ddr1 and lpddr1 u7233a-1fp u7233a-1tp n5435a-021 ddr2 and lpddr2 n5413b-1fp n5413b-1tp n5435a-037 ddr3 and lpddr3 u7231b-1fp u7231b-1tp n5435a-053 ddr4 and lpddr4 n6 462 a-1fp n6 462 a-1tp n5435a-056 displayport 1.2 u7232c-1fp u7232c-1tp n5435a-041 edp 1.4 n6 469a-1fp n6 469a-1tp n5435a-083 emmc n6 465a-1fp n6 465a-1tp n5435a-061 ethernet + eee 10/100/1000base-t n5392b-1fp n5392b-1tp n5435a-060 ethernet 10gbase-t u7236a-1fp u7236a-1tp n5435a-023 ethernet 10gbase-kr n8814b-1fp n8814b-1tp n5435a-059 ethernet 100gbase-cr10 n8 828a-1fp n8 828a-1fp n5435a-078 ethernet 100gbase-cr4 n8830a-1fp n8830a-1fp n5435a-080 ethernet 100gbase-kr4 n8829a-1fp n8829a-1fp n5435a-079 gddr5 u7245a-1fp u7245a-1tp hdmi 2.0 n5399c-1fp n5399c-1tp n5435a-070 mhl 3.0 n6 460b-1fp n6 460b-1tp n5435a-078 mipi d-phy u7238c-1fp u7238c-1tp n5435a-022 mipi m-phy u7249c-1fp u7249c-1tp n5435a-043 most n6466a-1fp n6466a-1tp n5435a-068 pci express gen 3 n5393d-1fp n5393d-1tp n5435a-040 sas-3 n5412d-1fp n5412d-1tp n5435a-073 sata gen 3 n5411b-1fp n5411b-1tp n5435a-028 sfp+ n6 468a-1fp n6 468a-1tp n5435a-074 usb 2.0 n5416a-1fp n5416a-1tp n5435a-017 usb 3.1 u724 3b-1fp u724 3b-1tp n5435a-075 usb hsic u724 8a-1fp u724 8a-1tp n5435a-042 uhs-i u7246a-1fp u7246a-1tp uhs-ii n6461a-1fp n6461a-1tp n5435a-052 user-defned application n5467b-1fp n5467b-1tp n5435a-058 thunderbolt n6 463b-1fp n6 463b-1tp n5435a-057 xaui n5431a-1fp n5431a-1tp n5435a-018 1. compliance software is not supported on dsaz632a, dsoz632a, dsaz592a and dsoz592a scope models.
27 | keysight | infniium z-series oscilloscopes - data sheet protocol analysis z-series oscilloscopes come with more than 15 protocol decoders, including the industrys only 64/66 b decoder. the z-series protocol tools feature time- correlated markers that let you easily move between the listing window and the waveform. protocol tools can be used on up to four lanes simultaneously. these unique tools feature search and trigger capability that lets you scan through the waveform to fnd the trigger condition that interests you. protocol tools are fully compatible with infniiums serial data analysis and are available on the infniium offine tool. z-series decoding the pci express gen 3 packets. protocol decode software description license type 8b/10b (generic) 1 1 1 64b/66b (10gbase-kr) n8815a-1fp n8815a-1tp n5435a-045 can/lin/flexray n8803a-1fp n8803a-1tp n5435a-033 ddr2/3/4 and lpddr2/3/4 2 2 2 i2c/spi 3 n5391a-1fp n5391a-1tp n5435a-006 jtag 3 n8817a-1fp n8817a-1tp n5435a-038 mipi csi-3 n8 820a-1fp n8 820a-1tp n5435a-065 mipi digrf ? v4 n8 807a-1fp n8 807a-1tp n5435a-047 mipi d-phy 3 n8 802 a-1fp n8 802 a-1tp n5435a-036 mipi lli n8 809a-1fp n8 809a-1tp n5435a-049 mipi rffe n8 824a-1fp n8 824a-1tp n5435a-072 mipi ufs n8818a-1fp n8818a-1tp n5435a-063 mipi unipro n8 808a-1fp n8 808a-1tp n5435a-048 pcie 1 and 2 n5463a-1fp n5463a-1tp n5435a-032 pcie 3 n8816a-1fp n8816a-1tp n5435a-046 rs-232/uart n5462a-1fp n5462a-1tp n5435a-031 sata n8 801a-1fp n8 801a-1tp n5435a-035 ssic n8819a-1fp n8819a-1tp n5435a-064 svid 3 n8812a-1fp n8812a-1tp n5435a-054 usb 2.0 n5464a-1fp n5464a-1tp n5435a-034 usb 3.0 n8 805a-1fp n8 805a-1tp n5435a-071 1. standard on dsa models or with high-speed sda option. 2. standard on mso models or with mso upgrade. 3. compliance software is not supported on dsaz632a, dsoz632a, dsaz592a, and dsoz592a scope models.
28 | keysight | infniium z-series oscilloscopes - data sheet achieve new extremes confgure your high-performance real-time oscilloscope solution today get the most out of your oscilloscope investment by choosing options and software to speed your most common tasks. use option numbers when ordering at time of purchase. use model numbers to add to an existing scope. 1. choose your oscilloscope oscilloscope description dsoz634a 63-ghz digital storage oscilloscope dsaz634a 63-ghz digital signal analyzer 1 dsoz632a 63-ghz digital storage oscilloscope dsaz632a 63-ghz digital signal analyzer 1 dsoz594a 59-ghz digital storage oscilloscope dsaz594a 59-ghz digital signal analyzer 1 dsoz592a 59-ghz digital storage oscilloscope dsaz592a 59-ghz digital signal analyzer 1 dsoz504a 50-ghz digital storage oscilloscope dsaz504a 50-ghz digital signal analyzer 1 dsoz334a 33-ghz digital storage oscilloscope dsaz334a 33-ghz digital signal analyzer 1 dsoz254a 25-ghz digital storage oscilloscope dsaz254a 25-ghz digital signal analyzer 1 dsoz204a 20-ghz digital storage oscilloscope dsaz204a 20-ghz digital signal analyzer 1 1. dsa models come standard with 100 mpts memory, ezjit complete and serial data analysis software. all models come with a front cover, power cord, keyboard, mouse, 3.5 mm male-to-male calibration cable (54916-61626), 3.5 mm (male) to 2.4 mm (male) calibration cable (54932-61630), esd strap, and (5) 3.5 mm female-to-female coax adapters (5061-5311). 50, 59, and 63 ghz models come with (2) additional 1.85 female-to-female adapters (54932-68712). all models come standard with removable ssd hard drive. description options model number 100 mpts/ch memory dsoz000-100 2 n2810a-100 2 200 mpts/ch memory dsoz000-200 n2810a-200 500 mpts/ch memory dsoz000-500 n2810a-500 1 gpt/ch memory dsoz000-01g n2810a-01g 2 gpts/ch memory dsoz000-02g n2810a-02g description options model number ansi z540 compliant calibration dsoz000-a6j iso17025 calibration dsoz000-1a7 performance verifcation de-skew fxture for infniimax iii probe n5443a rack mount kit option n2759a transit case n2748a removable ssd with windows 7 for z-series - 1 tb dsoz000-801 n2110a-01t removable ssd with windows 7 for z-series - 500 gb 3 n2110a-500 optional synchronization port for 20, 25, 33 ghz models dsoz000-601 2. standard on dsa models. 3. 500g ssd standard on all models.
29 | keysight | infniium z-series oscilloscopes - data sheet achieve new extremes (continued) confgure your high-performance real-time oscilloscope solution today 2. choose your probes and accessories probe amplifer description model number 30 ghz infniimax iii probe amplifer n2803a 25 ghz infniimax iii probe amplifer n2802a 20 ghz infniimax iii probe amplifer n2801a 16 ghz infniimax iii probe amplifer n2800a 20 ghz infniimax iii+ probe amplifer 1 n7003a 16 ghz infniimax iii+ probe amplifer 1 n7002a 13 ghz infniimax iii+ probe amplifer 1 n7001a 8 ghz infniimax iii+ probe amplifer 1 n7001a probe head description model number 16 ghz quicktip probe head 2 n2848a quicktip probe tip (set of 4) 2 n2849a 16 ghz solder-in probe head N5441A 26 ghz solder-in probe head 2 n2836a 28 ghz zero insertion force (zif) probe head n5439a 200 ? zif tip for high sensitivity 3 n5447a 25 ghz pc board zif tip (for normal sensitivity) n2838a 30 ghz browser probe head n5445a browser tip replacement (set of 4) n5476a 28 ghz 3.5 mm/2.92 mm/sma probe head 2 n5444a probe adapter description model number 30 ghz voltage termination adapter (50 ? 3.5 mm (f) to (m) connector) n7010a performance verifcation and deskew fxture n5443a precision bnc adapter (50 ? 3.5 mm (f) to precision bnc (f) connector) n5442a sampling scope adapter (50 ? 3.5 mm (f) to (m) connector) n5477a high-impedance probe adapter (includes one n2873a passive probe) n5449a for more information about infniium oscilloscope probes and accessories - data sheet, view the keysight publication number 5968-7141en. for more information about infniimax iii/iii+ probing system - data sheet, view the keysight publication number 5990-5653en. 1. with infniimode technology, allowing you to switch to differential, single-ended, and common mode without adjusting probe tip connections. 2. probe head that supports infniimode connections. 3. compatible only with infniimax iii probe amplifer.
30 | keysight | infniium z-series oscilloscopes - data sheet 3. upgrade your oscilloscope model numbers description upgrades within the z-series family n2764bu-025 bandwidth upgrade from 20 to 25 ghz n2764bu-033 bandwidth upgrade from 25 to 33 ghz n2764bu-050 bandwidth upgrade from 33 to 50 ghz n2764bu-059 bandwidth upgrade from 50 to 59 ghz n2764bu-062 bandwidth upgrade from 50 to 63 ghz n2764bu-162 bandwidth upgrade from 59 to 63 ghz note: all except 50 to 59 ghz and 50 to 63 ghz upgrades require return to service center but do not include service center costs. calibration incurs additional charges. number of channels model numbers description upgrades within the z-series family n2128a number of channel upgrade from 1-channel to 2-channel 59 or 63 ghz and 2-channel to 4-channel 33 ghz note: only applies to infniium z-series models dsaz632a, dsoz632a, dsaz592a, and dsoz592a. no return to service center is required. upgrade is software only. multi-frame options model numbers description upgrades within the z-series family n2107a infniium z-series multi-frame expansion kit from fve to six frames n2106a infniium z-series multi-frame expansion kit for adding one frame n2105a infniium z-series multi-frame base kit for stacking two frames n2109au infniium z-series sync port upgrade kit for 20 to 33 ghz models (> 33 ghz not needed) achieve new extremes (continued)
31 | keysight | infniium z-series oscilloscopes - data sheet specifcations vertical z204a z254a z334a z504a z592a z594a z632a z634a typical analog bandwidth (3 db) 20 ghz 25 ghz 33 ghz 50 ghz 59 ghz 59 ghz 63 ghz 63 ghz analog bandwidth (3 db) * 20 ghz 25 ghz 32 ghz 50 ghz 59 ghz 59 ghz 62 ghz 62 ghz 1-channel sample rate 80 80 80 160 160 160 160 160 2-channel sample rate 80 80 80 160 80 160 80 160 4-channel sample rate 80 80 80 80 80 80 rise time/fall time z204a z254a z334a z504a z592a z594a z632a z634a 10 to 90% 4 22.0 ps 17.6 p s 13.3 ps 8.8 ps 7.5 p s 7.5 p s 7.0 p s 7.0 p s 20 to 80% 5 15.6 ps 12.4 ps 9.4 ps 6.2 ps 5.3 ps 5.3 ps 4.9 ps 4.9 ps input impedance 3 50 ?, 3% sensitivity 2 1 mv/div to 1 v/div input coupling dc vertical resolution 1 8 bits, 12 bits with averaging channel to channel isolation (any two channels with equal v/div settings) replace existing channel to channel isolation specs with the following: realedge (1.85 mm) channels dc to 40 ghz: 70 db 40 ghz to bw: 60 db standard (3.5 mm) channels dc to bw: 70 db dc gain accuracy * 2% of full scale at full resolution channel scale ( 2.5% for 5 mv/div) maximum input voltage 5 v for steady state and transient measurements rms noise foor (scope only) z204a z254a z334a z504a z594a, z592a z634a, z632a volts/div 10 mv 0.41 mv (rms) 0.48 mv (rms) 0.60 mv (rms) 0.90 mv (rms) 0.96 mv (rms) 1.0 mv (rms) 50 mv 1.46 mv (rms) 1.7 mv (rms) 2.00 mv (rms) 2.90 mv (rms) 3.15 mv (rms) 3.3 mv (rms) 100 mv 2.90 mv (rms) 3.3 mv (rms) 3.90 mv (rms) 5.70 mv (rms) 6.2 mv (rms) 6.4 mv (rms) 1 v 28.6 mv (rms) 32.5 mv (rms) 38.1 mv (rms) 56.7 mv (rms) 60 mv (rms) 63 mv (rms) * d enotes warranted specifcations, all others are typical. specifcations are valid after a 30-minute warm up period, and 5 c from annual calibration temperature. 1. v ertical resolution for 8 bits = 0.4% of full scale, for 12 bits = 0.024% of full scale. 2. f ull scale is defned as 8 vertical divisions. magnifcation is used below 7.5 mv/div. below 7.5 mv/div, full-scale is defned as 60 mv/div. the major scale settings are 5 mv, 10 mv, 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, and 1 v. 3. i nput impedance is valid when v/div scaling is adjusted to show all waveform vertical values within scope display. 4. r ise time calculated by using 0.44/bw for (10 to 90%) rise time. 5. rise time calculated by using 0.31/bw for (20 to 80%) rise time. offset range vertical sensitivity available offset available offset (oscilloscope with n7010a voltage termination adapter) 1 to 49 mv/div 0.4 v 4 v 50 to 79 mv/div 0.7 v 4 v 80 to 134 mv/div 1.2 v 4 v 135 to 239 mv/div 2.2 v 4 v 240 mv/div to 1 v/div 4.0 v 4 v offset accuracy * 3.5 v: (2% of channel offset + 1% of full scale) + 1 mv > 3.5 v: (2% of channel offset + 1% of full scale) dynamic range 4 div from center screen dc voltage measurement accuracy dual cursor: [(dc gain accuracy) + (resolution)] single cursor: [(dc gain accuracy) + (offset accuracy) + (resolution/2)]
32 | keysight | infniium z-series oscilloscopes - data sheet specifcations (continued) horizontal horizontal system: oscilloscope channels main timebase range 2 ps/div to 200 s/div main timebase delay range 0 s 200 s real time reference position continuously adjustable across horizontal display range zoom timebase range 1 ps/div to current main time scale setting time scale accuracy 1, 8 (0.1 ppm initial + 0.1 ppm/year aging) oscilloscope channel de-skew range 1 ms range, 10 fs resolution intrinsic jitter 6 (sample clock jitter) acquired time range or delta-time interval internal reference external reference < 10 s (1 s/div) 50 fs rms 50 fs rms (z502a/z592a/z632a 75 fs rms 75 fs rms (z204a/z254a/z334a) 100 s (10 s/div) 75 fs rms 75 fs rms 1 ms (100 s/div) 100 fs rms 100 fs rms 10 ms (1 ms/div) 150 fs rms 125 fs rms 100 ms (10 ms/div) 200 fs rms 150 fs rms 1 s (100 ms/div) 150 fs rms inter-channel intrinsic jitter 3 < 50 fs rms inter-channel skew drift 3, 7 < 50 fs rms jitter measurement foor 2 C time interval error ( ) 2 2 intrinsic jitte r? noise floor slew rate + ? ? ? ? ? ? C period jitter ( ) 2 2 2 ? noise floor intrinsic jitter slew rate + ? ? ? ? ? ? ? C cycle-cycle/n-cycle jitter ( ) 2 2 3 ? noise floor intrinsic jitter slew rate + ? ? ? ? ? ? ? inter-channel jitter measurement foor 2, 3, 5 ( ) ( ) 2 2 2 1 2 time interval time interval inter channel error edge error edge intrinsic jitter + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 1. denotes warranted specifcations, all others are typical. specifcations are valid after a 30-minute warm-up period and 5 c from frmware calibration temperature. 2. sample rate at maximum. noise and slew rate determined at fxed-voltage measurement threshold, near middle of signal. displayed signal not vertically clipped. slew rate of sine wave = (peak signal amplitude) ? 2 ? ? f, slew rate of fast step ~= (10 to 90% rise time). 3. intra-channel = both edges on the same channel, inter-channel = two edges on different channels. time interval error(edge1) = time-interval error measurement foor of frst edge, time interval error(edge2) = time-interval error measurement foor of second edge. 4. reading is the displayed delta time measurement accuracy measurement value. do not double the listed time scale accuracy value in delta time measurement accuracy formula. 5. scope channels and signal interconnect de-skewed prior to measurement. 6. external timebase reference values measured using a wenzel 501-04608a 10 mhz reference. intrinsic jitter value depends on acquisition time range for time interval error formula and depends on delta-time between edges for all two-edge formulas. 7. skew between channels caused by 5 c temperature change. 8. initial = immediately after factory or user calibration.
33 | keysight | infniium z-series oscilloscopes - data sheet specifcations (continued) horizontal (continued) horizontal system: oscilloscope channels (continued) delta time measurement accuracy 2, 3, 4, 5 C intra-channel C no averaging ( ) ( ) 2 2 5 ? ? ? 1 2 time interval time interval time scale delta error edge error edge accuracy time ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C 256 averages ( ) ( ) 2 2 ? ? ? 5 1 2 16 time interval time interval time scale delta error edge error edge accuracy time ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C inter-channel C no averaging ( ) ( ) 2 2 2 5 ? 1 2 time interval time interval inter channel error edge error edge intrinsic jitter time scale delta inter channel accuracy time skew drift ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? C 256 averages ( ) ( ) 2 2 2 ? ? ? ? 5 1 2 16 time interval time interval inter channel error edge error edge intrinsic jitter time scale delta inter channel accuracy time skew drift ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + + ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2. s ample rate at maximum. noise and slew rate determined at fxed-voltage measurement threshold, near middle of signal. displayed signal not vertically clipped. slew rate of sine wave = (peak signal amplitude) ? 2 ? ? f, slew rate of fast step ~= (10 to 90% rise time). 3. i ntra-channel = both edges on the same channel, inter-channel = two edges on different channels. time interval error(edge1) = time-interval error measurement foor of frst edge, time interval error(edge2) = time-interval error measurement foor of second edge. 4. r eading is the displayed delta time measurement accuracy measurement value. do not double the listed time scale accuracy value in delta time measurement accuracy formula. 5. s cope channels and signal interconnect de-skewed prior to measurement.
34 | keysight | infniium z-series oscilloscopes - data sheet acquisition z204a, z254a, z334a z592a, z632a z504a, z594a, z634a maximum real-time sample rate 1 channels 80 gsa/s 160 gsa/s 160 gsa/s 2 channels 80 gsa/s 80 gsa/s 160 gsa/s 4 channels 80 gsa/s 80 gsa/s memory depth per channel 4 channels (z204a, z254a, z334a, z504a, z594a, z634a) and 2 channels (z592a, z632a) 2 channels (z204a, z254a, z334a, z504a, z594a, z634a) and 1 channel (z592a, z632a) standard 50 mpts 100 mpts option 100 100 mpts (standard on dsa models) 200 mpts (standard on dsa models) option 200 200 mpts 400 mpts option 500 500 mpts 1 gpt option 01g 1 gpt 1 gpt option 02g 2 gpts 2 gpts maximum acquired time at highest real-time resolution real-time resolution 80 gsa/s 160 gsa/s resolution 12.5 ps 6.25 ps standard (20 m) 0.25 ms 0.125 ms option 50 m 0.625 ms 0.3125 ms option 100 1.25 ms 0.625 ms option 200 2.5 ms 1.25 ms option 500 6.25 ms 3.125 ms option 01g 12.5 ms 6.25 ms option 02g 25 ms 12.5 ms sampling modes real-time successive single shot acquisitions real-time with averaging selectable from 2 to 65534 (up to 200,000 with function) real-time with peak detect 80 gsa/s (unavailable on realedge channels) real-time with hi resolution real-time boxcar averaging reduces random noise and increases resolution (unavailable on realedge channels) gaussian magnitude, linear phase slower flter roll off while maintaining linear phase roll mode scrolls sequential waveform points across the display in a right-to-left rolling motion. works at sample rates up to 10 msa/s with a maximum record length of 40 mpts segmented memory captures bursting signals at max sample rate without consuming memory during periods of inactivity number of segments (up to 131,072 with > 500 m of memory depth) maximum time between triggers is 562,950 seconds re-arm time: 2.5 s maximum memory depth: up to 8 gpts in 1/2 channel mode with option 02g filters sin(x)/x interpolation on/off selectable fir digital flter (2x, 4x, 8x, 16x settings). digital signal processing adds points between acquired data points to enhance measurement accuracy and waveform display specifcations (continued)
35 | keysight | infniium z-series oscilloscopes - data sheet hardware trigger sensitivity internal low: 2.0 div p-p 0 to 22 ghz internal high: 0.3 div p-p 0 to 18 ghz, 1.0 div p-p 0 to 22 ghz edge trigger bandwidth > 20 ghz minimum pulse width trigger hardware < 250 ps software (infniiscan) 40 ps level range internal 4 div from center screen or 4 v, whichever is smaller auxiliary 5 v, also limit input signal to 5 v sweep modes auto, triggered, single display jitter 2, 3, 4 (trigger jitter) 170 fs rms trigger sources channel 1, channel 2, channel 3, channel 4, aux trigger modes edge triggers on a specifed slope (rising, falling or alternating between rising and falling) and voltage level on any channel or auxiliary trigger. edge trigger bandwidth is > 20 ghz edge transition trigger on rising or falling edges that cross two voltage levels in > or < the amount of time specifed. edge transition setting from 250 ps edge then edge (time) the trigger is qualifed by an edge. after a specifed time delay between 10 ns to 10 s, a rising or falling edge on any one selected input will generate the trigger edge then edge (event) the trigger is qualifed by an edge. after a specifed delay between 1 to 16,000,000 rising or falling edges, another rising or falling edge on any one selected input will generate the trigger glitch triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. triggers on glitches as narrow as 125 ps. glitch range settings: < 250 ps to < 10 s pulse width trigger on a pulse that is wider or narrower than the other pulses in your waveform by specifying a pulse width and a polarity. triggers on pulse widths as narrow as 125 ps. pulse width range settings 250 ps to 10 s. trigger point can be end of pulse or time out runt triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the frst again. can be time qualifed with minimum setting of 250 ps 1. denotes warranted specifcations, all others are typical. specifcations are valid after a 30-minute warm-up period and 5 c from frmware calibration temperature. 2. internal edge trigger mode with jitterfree correction. value depends on scope settings and trigger signal characteristics, and is equal to time interval error value expressed in the formula above using the minimum time scale accuracy value. 3. value shown represents typical display jitter for dsoz334a at 100 mv/div triggering on 500 mvpp 16 ghz sin wave signal. 4. sample rate at maximum. noise and slew rate determined at fxed-voltage trigger threshold, near middle of signal. displayed signal not vertically clipped. specifcations (continued)
36 | keysight | infniium z-series oscilloscopes - data sheet hardware trigger (continued) timeout trigger when a channel stays high, low, or unchanged for too long. timeout setting: from 250 ps to 10 s pattern/pulse range triggers when a specifed logical combination of the channels is entered, exited, present for a specifed period of time or is within a specifed time range or times out. each channel can have a value of high (h), low (l) or dont care (x) state pattern trigger clocked by the rising, falling or alternating between rising and falling edge of one channel window triggers on an event associated with a window defned by two-user adjustable thresholds. event can be window entered, exited, inside (time qualifed), or outside (time qualifed) voltage range. trigger point can be cross window boundary or time out. time qualify range: from 250 ps to 10 s video triggers from negative sync composite video, feld 1, feld 2, or alternating felds for interlaced systems, any feld, specifc line, or any line for interlaced or non-interlaced systems. supports ntsc, pal-m (525/60), pal, secam (625/50), edtv (480p/60), edtv (576p/50), hdtv (720p/60), hdtv (720p/50), hdtv (1080i/60), hdtv (1080i/50), hdtv (1080p/60), hdtv (1080p/50), hdtv (1080p/30), hdtv (1080p/25), hdtv (1080p/24), and user-defned formats trigger sequences three-stage trigger sequences including two-stage hardware (find event (a) and trigger event (b)) and one-stage infniiscan software trigger. supports all hardware trigger modes except edge then edge and video, and all infniiscan software trigger modes. supports delay (by time) and reset (by time or event) between two hardware sequences. the minimum latency between fnd event (a) and trigger event (b) is 3 ns trigger qualifcation and qualifer single or multiple channels may be logically qualifed with any other trigger mode trigger holdoff range 100 ns to 10 s trigger actions specify an action to occur and the frequency of the action when a trigger condition occurs. actions include email on trigger and execute multipurpose user setting software trigger (requires n5414b infniiscan event identifcation software C option 009) trigger modes zone qualify software triggers on the user-defned zones on screen. zones can be specifed as either must intersect or must not intersect. up to eight zones can be defned across multiple channels generic serial software triggers on nrz-encoded data up to 8.0 gbps, up to 80-bit pattern. support multiple clock data recovery methods including constant frequency, 1st-order pll, 2nd-order pll, explicit clock, explicit 1st-order pll, explicit 2nd-order pll, fibre channel, flexray receiver, flexray transmitter (requires e2688a except for the constant frequency clock data recovery mode) measurement limit software triggers on the results of the measurement values. for example, when the pulse width measurement is turned on, infniiscan measurement software trigger triggers on a glitch as narrow as 40 ps. when the time interval error (tie) is measured, infniiscan can trigger on a specifc tie value non-monotonic edge software triggers on the non-monotonic edge. the non-monotonic edge is specifed by setting a hysteresis value runt software triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the frst again. unlike hardware runt trigger, infniiscan runt trigger can be further qualifed via a hysteresis value specifcations (continued)
37 | keysight | infniium z-series oscilloscopes - data sheet hardware trigger (continued) maximum measurement update rate > 50,000 measurement/sec (one measurement turned on) > 250,000 measurement/sec/measurement (ten measurements turned on) measurement modes standard, measure all edges mode waveform measurements voltage peak to peak, minimum, maximum, average, rms, amplitude, base, top, overshoot, preshoot, upper, middle, lower, vovershoot, vtime, vpreshoot, crossing, pulse base, pulse amplitude, pulse top, pam level mean 2 , pam level rms 2 , pam level skew 2 , pam level thickness 2 time rise time, fall time, positive width, negative width, burst width, burst period, burst interval, tmin, tmax, tvolt, + pulse count, - pulse count clock period, frequency, duty cycle to duty cycle, phase, n-period data setup time, hold time mixed area, slew rate frequency domain fft frequency, fft magnitude, fft delta frequency, fft delta magnitude, peak detect mode level qualifcation any channels that are not involved in a measurement can be used to level-qualify all timing measurements eye-diagram measurements eye height, eye width, eye jitter, crossing percentage, q factor, and duty-cycle distortion jitter analysis measurements requires option 002 (or e2681a), 004 (n5400a), or 070 (n8823a). standard on dsa series clock time interval error, n-period, period to period, positive width to positive width, neg width to neg width, and duty cycle to duty cycle data time interval error, unit interval, n unit interval, unit interval to unit interval, data rate, cdr, de-emphasis statistics displays the current, mean, minimum, maximum, range (max-min), standard deviation, number of measurements value for the displayed automatic measurements histograms source waveform or measurement orientation vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defned using waveform markers measurements (available as a function) mean, standard deviation, mean 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of most hits), x scale hits, and x offset hits mask testing allows pass/fail testing to user-defned or keysight-supplied waveform templates. automask lets you create a mask template from a captured waveform and defne a tolerance range in time/voltage or screen divisions. test modes (run until) include test forever, test to specifed time or event limit, and stop on failure. executes multipurpose user setting on failure unfold real-time eye feature allows individual bit errors to be observed by unfolding a real-time eye when clock recovery is on communications mask test kit option provides a set of itu-t g.703, ansi t1.102, and ieee 802.3 industry-standard masks for compliance testing waveform math number of functions sixteen hardware accelerated math operations differential and common mode absolute value, add, amplitude demodulation (radar envelope), average, butterworth 1 , common mode, delay, differentiate, divide, fft magnitude, fft, phase, fir 1 , high pass flter, histogram, horizontal gating, integrate, invert, lfe 1 , low pass flter (4th-order bessel thompson flter), magnify, max, measurement trend, min, multiply, rt eye 1 , smoothing, sqrtsumofsquare 1 , square, square root, subtract, versus, and optional user defned function (option 010) fft frequency range dc to 80 ghz (at 160 gsa/s) or 40 ghz (at 80 gsa/s) or 20 ghz (at 40 gsa/s) frequency resolution sample rate/memory depth = resolution window modes hanning, fattop, rectangular, blackman-harris, hamming 1. requires ezjit plus (option n5400a) or ezjit complete (option n8823a) software. 2. requires pam-4 analysis (option n8827a) software. specifcations (continued)
38 | keysight | infniium z-series oscilloscopes - data sheet hardware trigger (continued) measurement modes automatic measurements measure menu access to all measurements, up to 20 measurements can be displayed simultaneously multipurpose front-panel button activates up to ten pre-selected or up to ten user-defned automatic measurements drag-and-drop measurement toolbar measurement toolbar with common measurement icons that can be dragged and dropped onto the displayed waveforms marker modes manual markers, track waveform data, track measurements bookmarks and callouts supports callouts for measurements and fft peaks. supports bookmarks for team collaboration display display 15.4-inch color xga tft-lcd with capacitive touch screen intensity grayscale 256-level intensity-graded display resolution xga 1024 pixels horizontally x 768 pixels vertically annotation up to 100 bookmarks can be inserted into the waveform window. each can foat or be tied to a specifc waveform grids choose between 1-16 grids per waveform area, 8 bit vertical resolution waveform styles connected dots, dots, infnite persistence, color graded infnite persistence. includes up to 256 levels of intensity- graded waveforms., variable persistence waveform area supports eight waveform areas plus chart mode for ezjit plus, infniisim, protocol, and precisionprobe maximum update rate > 400,000 waveforms per second (when in the segment memory mode) computer system and peripherals, i/o ports computer system and peripherals operating system windows 7 64-bit cpu intel i5-3550s quad-core cpu at 3.00 ghz pc system memory 16 gb ddr3 ram drives (ssd) 500-gb internal hard drive removable hard drive, additional hard drives (n2110a) peripherals logitech optical usb mouse, compact usb keyboard supplied. all infniium models support any windows- compatible input device with a serial, ps/2 or usb interface. file types waveforms compressed internal format (*.wfm (200 mpts)), comma-separated values (*.csv (2 gpts)), tab-separated values (*.tsv (2 gpts)), public binary format (.bin (500 mpts)), y value fles (*.txt (2 gpts)), hierarchal data fle (*.hf5 (2 gpts)), composite data fle (*.osc (2 gpts)) images bmp, png, tiff, gif, jpeg or osc fle format i/o ports rs-232 (serial), parallel, ps/2, usb 2.0 hi-speed (host), usb 2.0 hi-speed (device), vga, displayport, usb 3.0, dual-monitor video output, auxiliary output, trigger output, time base reference output specifcations (continued)
39 | keysight | infniium z-series oscilloscopes - data sheet general characteristics temperature operating: 5 to + 40 c; non-operating: C40 to +65 c humidity operating: up to 95% relative humidity (non-condensing) at +40 c non-operating: up to 90% relative humidity at +65 c altitude operating: up to 4,000 meters (12,000 feet); non-operating: up to 15,300 meters (50,000 feet) vibration operating random: 00.21 g (rms) non-operating random: 2.0 g (rms) swept sines: (0.50 g) power 100 to 240 vac 10% at 50/60 hz maximum input power 1350 w well-regulated power is required for 100 to 120 vac operation weight 32.2 kg (71 lbs) dimensions height: 33.8 cm (13.3 in); width: 50.8 cm (20 in); depth: 49.3 cm (19.4 in) safety can/csa-c22.2 no. 61010-1-04 ul std. no. 61010-1 (2nd edition) keysight oscilloscopes multiple form factors from 20 mhz to > 90 ghz | industry leading specs | powerful applications specifcations (continued)
40 | keysight | infniium z-series oscilloscopes - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. the business that became keysight was a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. the business that became keysight was a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system.
41 | keysight | infniium z-series oscilloscopes - data sheet this information is subject to change without notice. ? keysight technologies, 2013 - 2016 published in usa, october 5, 2016 5991-3868en www.keysight.com for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp- 09-23-16) dekra certified iso9001 quality management system www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2015 quality management system mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. keysight services www.keysight.com/find/service our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. the result? we help you implement new technologies and engineer improved processes that lower costs. three-year warranty www.keysight.com/find/threeyearwarranty keysights committed to superior product quality and lower total cost of ownership. keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. and, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. mipi ? service marks and logo marks are owned by mipi alliance, inc. and any use of such marks by keysight technologies is under license. other service marks and trade names are those of their respective owners. pci-sig ? , pcie ? and the pci express ? are us registered trademarks and/or service marks of pci-sig. www.keysight.com/find/z-series evolving our unique combination of hardware, software, support, and people can help you reach your next breakthrough. we are unlocking the future of technology. from hewlett-packard to agilent to keysight


▲Up To Search▲   

 
Price & Availability of N5441A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X